SERIES 1800: Single Open-Ended Sample Cups with ThermoPlastic® seal venting

SERIES 1800: Single Open-Ended Sample Cups with ThermoPlastic® seal venting

SERIES 2100: Double Open-Ended SpectroCup® Sample Cups

SERIES 2100: Double Open-Ended SpectroCup® Sample Cups

SERIES 1900: Double Open-Ended Sample Cups with Snap-On Ring

Double open-ended Cell facilitates sample introduction by filling from the top end. Prepare multiple samples cups in advance with thin-film sample support windows prior to filling. Ideally suitable for non-volatile liquid and loose powdered materials in helium flush or atmospheric conditions.

Features

Double Open-ended

Top sample loading

Available in nominal 32 and 40mm diameters

"Snap-On Ring" thin-film attachment

Serrated edged “Snap-On Rings” alternatively available to facilitate thin-film trimming

Use with Oxford/Hitachi Instruments with and without Aluminum sample holder

Package

100 sets per package

Quantity Discount

Order 20-39 packages and receive $5.00 off standard price per package

Order 40 or more and receive $10.00 off standard price per package

Made in USA

Double open-ended Cell facilitates sample introduction by filling from the top end. Prepare multiple samples cups in advance with thin-film sample support windows prior to filling. Ideally suitable for non-volatile liquid and loose powdered materials in helium flush or atmospheric conditions.

 The Collar provided pre-affixes a thin-film substrate to the Cell in preparation for attaching the furnished locking “Snap-On Ring.” Alternatively, a pre-attached thin-film may be used to support evaporated droplets or micro powdered samples for thin-layered preparations enveloped in between another thin-film with both secured in place by the attachment of the included “Snap-On Ring.”

 The “Snap-On Ring” and Cell neck utilize the unique Chemplex® “bead-to-indent” geometry responsible for firmly securing thin-film sample support window planes to the sample cup Cell. In combination they form wrinkle-free sample planes and leak-resistant seals.

 Alternatively available nominal 32mm diameter sample cups with integrated serrated edged "Snap-On Rings" that allow extraneous thin-film trimming close to the sample cup. Order by catalog number followed by "SE".

 * Reg. US Patent No: 7,981,380 B2

 ® ThermoPlastic, SpectroMembrane, the Wizard character and Chemplex are registered trademarks of Chemplex Industries, Inc.

*Please see the "Additional Info" tab for analyzer equipment compatibility details.

More Information

Instrument Compatibility

The following table lists some known sample cup compatibilities and provided for reference purposes. This is not an exhaustive list and serves as a guideline. Please check dimensions of the sample holder and compare them to the sample cup dimensions. Samples are available upon request to verify sample cup compatibilities.

Manuf Models Sample Cup Cat No
Bruker S2 Puma 2140, 2143, 2144 & 2154
Bruker S2 Puma w/ Xflash 2143, 2144 & 2154
Bruker S2 Ranger 2143
Bruker S4 2140
Bruker S8 w/ Flex Loader 2143, 2144 & 2154
Bruker S8 Tiger 2143, 2144, 2154, 1095 & 2195
Horiba SLFA Units 1850, 1083 & 1084
Horiba 6100/6800/60A 1086 & 1087
Horiba Mesa 7220 1083, 1850 & 3130 ( use 7220-P or 7220-S locating ring)
Innov-X Hand Held Units 1330, 1330-SE & 1340
Oxford Lab-X 1940L, 1940-ox
Oxford MDX 1935-ox, 1940-ox
Oxford Replacement Cells 54-LX6922 1440L
Oxford Replacement Cells & Covers: 54-CK-100 1935-ox
Oxford Replacement Cells & Covers: 54-CK-100 and L242 Holder 1940-ox
Malvern Panalytical Epsilon 3XL, MiniPal 2135
Malvern Panalytical Axios P2
Malvern Panalytical Epsilon 5 2145, 2146
Malvern Panalytical Venus 200 1095, 2195
Rigaku Mini-Z

2140

Rigaku Primus, Rix, ZSX-100

1095, 2195

Spectro XEPOS, Xepos Low S, Xepos IQ, X-Lab 2000, 200, 200T Titan, Phoenix 1060, 1065, 1070, 1075, Series 1300, Series 1400, Series 1500, Series 1700, Series 1800, 1930, 1930-SE, 1940, 2131, 2135
Spectro IQ 2132
Spectro Phoenix II 2131
Spectro Scout 3106, 3110, 3115 & 3120
Thermo Advant'x 2146
Xenemetrix X-Calibur, X-Cite 2131, 2132, 2132S, 1540
XOS Sindie®, Clora, Signal, HD Maxine, Phoebe, Petra 1083, 1084 & 1850
XOS Sindie 3rd Generation 3130 & 3132

Recycling

Chemplex® XRF sample cups are made from virgin HDPE and can be recycled. Please contact your local county or municipality to determine your local recycling options and procedures.

Recycle_2_HDPE

® Sindie, Clora, HD Maxine, Phoebe, Signal are registered trademarks of XOS Inc.

No
Write Your Own Review
You're reviewing:SERIES 1900: Double Open-Ended Sample Cups with Snap-On Ring
Your Rating
Grouped product items
Cat. No. Open Ends Outside Dia. Max O.D. Aperture Vol Height Price Price for
Qty 20+
Price for
Qty 40+
Qty
1930
Double
1.25" (31.4mm)
1.25" (31.4mm)
0.96" (24.4mm)
8
0.84" (21.3mm)
$50 $45 $40
1930-SE
Double
1.25" (31.4mm)
1.25" (31.4mm)
0.96" (24.4mm)
8
0.84" (21.3mm)
$50 $45 $40
1935-OX
Double
1.23" (31.2mm)
N/A
1.13" (28.7mm)
25ml
1.51" (38.4mm)
$65 $60 $55
1940
Double
1.55" (39.4mm)
1.55" (39.4mm)
1.27" (32.3mm)
15
0.84" (21.3mm)
$60 $55 $50
1940L
Double
1.55" (39.4mm)
1.55" (39.4mm)
1.27" (32.3mm)
25ml
1.39" (35.3mm)
$65 $60 $55
1940-OX
Double
1.61" (40.8mm)
N/A
1.13" (28.7mm)
25ml
1.51" (38.4mm)
$65 $60 $55