1085: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Single Open End; 1.69

1085: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Single Open End; 1.69" (42.9mm) Dia X 0.80" (20.3mm) Height, 100/Pkg

1084: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Stackable, Single Open End, w/ Vent Hole; 1.69

1084: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Stackable, Single Open End, w/ Vent Hole; 1.69" (42.9mm) Dia X 0.73" (18.5mm) Height, 100/Pkg

1095: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Double Open Ends; 1.71" (43.4mm) Dia X 1.57" (39.9mm) Height, 100/Pkg

$65.00
Availability: In stock
SKU
1095
  • Buy 20 for $60.00 each and save 8%
  • Buy 40 for $55.00 each and save 15%

Choice of double open-ended Cell for pre-attaching thin-film sample support windows, top sample filling and use in inert helium flush or atmospheric pressure.

Features

TrimLess® sleeve completely envelops the thin-film

Eliminates thin-film trimming

No annoying clippings and static cling

ThermoPlastic® seal venting

Available in Single & Double Open-Ends

Package

100 sets per package

Quantity Discount

Order 20-39 packages and receive $5.00 off standard price per package

Order 40 or more and receive $10.00 off standard price per package

Made in USA

Choice of single-open ended Cell with Integrated External Overflow Reservoir and a ThermoPlastic® Seal. Simply puncture the ThermoPlastic® seal to vent the sample cup to equalize the pressure within the sample cup and sample chamber and maintain a taut thin-film sample support plane during analysis.

The double open-ended version enables pre-attachment of thin-film sample support windows and the convenience of top sample filling for use in inert helium flush or atmospheric pressure. The Integrated Flanges on the Cell and Sleeve serve several functions:

• Ease of handling

• Indicate which end of the sleeve is slipped on the Cell first.

• Complete envelopment of the thin-film sample support substance in between the sleeve and cell neck. There is no extraneous thin-film to trim and contend with the clippings and annoying static cling.

• Ensure correct assembly of the sample cup with the open ends of the Sleeve and Cell Neck on the same plane.

Catalog number 1095 is also included in the TrimLess® Sample Cup Series. It boasts a double open-ended sample cell for pre-attachment of thin-film sample support windows and includes a vented friction fitting cap with a knob.

An alternate to the 1095 sample cup is the 2195 SpectroCup® Integrated Internal Overflow Reservoir. The Integrated Internal Overflow Reservoir is designed to collect any overfills within the Cell. The 1095 and 2195 are both comparable in use and applications for Rigaku, PANalytical Venus 200 systems and other x-ray units with sample cup holders accepting similar dimensions.

® SpectroSulfur, SpectroCup, TrimLess, ThermoPlastic and Chemplex are registered trademarks of Chemplex Industries, Inc.

*Please see the "Additional Info" tab for sample cup compatibility details.

More Information

Instrument Compatibility

The following table lists some known sample cup compatibilities and provided for reference purposes. This is not an exhaustive list and serves as a guideline. Please check dimensions of the sample holder and compare them to the sample cup dimensions. Samples are available upon request to verify sample cup compatibilities.

Manuf Models Sample Cup Cat No
Bruker S2 Puma 2140, 2143, 2144 & 2154
Bruker S2 Puma w/ Xflash 2143, 2144 & 2154
Bruker S2 Ranger 2143
Bruker S4 2140
Bruker S8 w/ Flex Loader 2143, 2144 & 2154
Bruker S8 Tiger 2143, 2144, 2154, 1095 & 2195
Horiba SLFA Units 1850, 1083 & 1084
Horiba 6100/6800/60A 1086 & 1087
Horiba Mesa 7220 1083, 1850 & 3130 ( use 7220-P or 7220-S locating ring)
Innov-X Hand Held Units 1330, 1330-SE & 1340
Oxford Lab-X 1940L, 1940-ox
Oxford MDX 1935-ox, 1940-ox
Oxford Replacement Cells 54-LX6922 1440L
Oxford Replacement Cells & Covers: 54-CK-100 1935-ox
Oxford Replacement Cells & Covers: 54-CK-100 and L242 Holder 1940-ox
Malvern Panalytical Epsilon 3XL, MiniPal 2135
Malvern Panalytical Axios P2
Malvern Panalytical Epsilon 5 2145, 2146
Malvern Panalytical Venus 200 1095, 2195
Rigaku Mini-Z

2140

Rigaku Primus, Rix, ZSX-100

1095, 2195

Spectro XEPOS, Xepos Low S, Xepos IQ, X-Lab 2000, 200, 200T Titan, Phoenix 1060, 1065, 1070, 1075, Series 1300, Series 1400, Series 1500, Series 1700, Series 1800, 1930, 1930-SE, 1940, 2131, 2135
Spectro IQ 2132
Spectro Phoenix II 2131
Spectro Scout 3106, 3110, 3115 & 3120
Thermo Advant'x 2146
Xenemetrix X-Calibur, X-Cite 2131, 2132, 2132S, 1540
XOS Sindie®, Clora, Signal, HD Maxine, Phoebe, Peta 1083, 1084 & 1850
XOS Sindie 3rd Generation 3130 & 3132

Recycling

Chemplex® XRF sample cups are made from virgin HDPE and can be recycled. Please contact your local county or municipality to determine your local recycling options and procedures.

HDPE

® Sindie, Clora, HD Maxine, Phoebe, Signal are registered trademarks of XOS Inc.

No
Write Your Own Review
You're reviewing:1095: SpectroSulfur® Analyzer TrimLess® XRF Sample Cups, Double Open Ends; 1.71" (43.4mm) Dia X 1.57" (39.9mm) Height, 100/Pkg
Your Rating